while level 3 (warning) logs unexpected events that can be
handled. Unhandled error conditions are logged with loglevel
4 (error) and crititcal errors are logged using loglevel 5
- (crit). Finally, loglevel 6 (emerg) is reserved for messages
+ (crit). Finally, loglevel 6 (emerg) is reserved for messages
that cause para_server to terminate immediately.
"
multiple
optional
details="
- Example: --log_color \"INFO:yellow black bold\"
+ The format of \"color_spec\" is [fg [bg]] [attr].
+
+ Valid colors for \"fg\" and \"bg\" are \"normal\", \"black\",
+ \"red\", \"green\", \"yellow\", \"blue\", \"magenta\",
+ \"cyan\", and \"white\".
+
+ The \"attr\" value must be one of \"bold\", \"dim\", \"ul\",
+ \"blink\", \"reverse\".
+
+ Examples:
+
+ --log_color \"debug:green\"
+ --log_color \"info:yellow bold\"
+ --log_color \"notice:white red bold\"
"
option "port" p
of 'name'. As the configuration file is read afterwards,
those options that have a default value depending on the UID
(e.g. the directory for the configuration file) are computed
- by using the uid of 'name'. This option has no effect if
+ by using the uid of 'name'. This option has no effect if
para_server is started as a non-root user (i.e. EUID != 0)
"